Antimony Pentaoxide Colloidal
Chemico A - 40 : Sb2O5 Flame Retardant Additives
(CAS No. : 1314 - 60 - 9)
| Product Description |
|
Chemico A - 40 are water - based
dispersions of nano-sized Antimony Pentaoxide used with
halogenated flame retardants to increase their efficiency when
used in flame retardant treatments of materials such as
textiles, nonwovens, adhesive latices, and coatings.
|
| Compounding Information |
|
Neoprene - type of PVDC lattices often
recommend avoiding the use of ammonia. A 15% solution of sodium
hydroxide can be used or use Chemico A - 40 which is neutralized
with sodium hydroxide.
|
| Properties |
| Antimony Pentaoxide Sb2O5 |
38% |
| pH |
8 |
| Viscosity in centipoises |
5 |
| Specific Gravity |
1.60 |
|
| For further information
please contact:- |
Mr. B. K. Jain
Director - Technical
Tel. :- (0091) (11) 22167148, 22143971/81
Mobile :- 9810005428
E-mail :
chemico@del2.vsnl.net.in |
|
| Formulating Guidelines |
|
The total amount and ratio of flame
retardants needed depend upon the severity of the test
requirements and the material being treated. In most cases,
optimum flame retardant performance in a halogen/antimony system
is attained when the halogen and antimony are used at a 3 : 1
mole ratio. Exceptions are PVC and PVCD latices which contain
high levels of chlorine, so we recommend the antimony pentaoxide
be added to your formulation until the complete system passes
the required flame test.
|
| Formula Example |
|
This simple FR application for the
finishing of nonwoven polyester fiber padding for automotive
interiors consists of a 'hard' PVC latex, Chemico A - 40,
water and some ammonia solution : To 10 parts Chemico A-40,
add 40 parts water with sufficient ammonia to bring the pH to 9,
mix the water and the A-40, add 50 parts PVC latex.
These ingredients are mixed, sprayed onto the nonwoven padding,
and heat cured.
|
| Benefits |
- Better penetration of the substrate.
- Less pigmenting or whitening effect for deep mass tone
colours.
- Easier handling and processing. Liquid dispersion will
not clog spray guns.
- Translucency for coatings, films and laminates.
- Easy compounding : no special dispersing equipment
required.
- High FR efficiency for minimal added weight or change in
hand.
|
|
Antimony Pentaoxide Colloidal
Chemico A - 50 : Sb2O5 Flame Retardant Additives
(CAS No. : 1314 - 60 - 9)
| Product
Description |
|
Chemico A - 50 are water - based
dispersions of nano-sized Antimony Pentaoxide used with
halogenated flame retardant to increase their efficiency when
used in flame retardant treatments of materials such as
textiles, non wovens, adhesive lattices, and coatings.
|
| Compounding
Information |
|
Chemico A-50 aqueous dispersions
are supplied at approximately pH5 and, in nearly all
applications, should have the pH adjusted before compounding
with any latex. This adjustment assures full utilization of the
colloidal particles without agglomeration or latex
destabilization. Follow the latex manufactures recommendations
for the optimum pH. Neutralize using ammonium hydroxide, which
will volatilize during the drying and curing of latex film.
Chemico A-50 :
Dilute with water to 40% Sb2O5 or less,
then neutralize with ammonia hydroxide.
|
| Properties |
| Antimony Pentaoxide Sb2O5 |
48% |
| pH |
5 |
| Viscosity in centipoises |
5 |
| Specific Gravity |
1.81 |
|
| For
further information please contact:- |
Mr. B. K. Jain
Director - Technical
Tel. :- (0091) (11) 22167148, 22143971/81
Mobile :- 9810005428
E-mail :
chemico@del2.vsnl.net.in |
|
| Formulating
Guidelines |
|
The total amount and ratio of flame
retardants needed depend upon the severity of the test
requirements and the material being treated. In most cases,
optimum flame retardant performance in a halogen/antimony system
is attained when the halogen and antimony are used at a 3 : 1
mole ratio. Exceptions are PVC and PVCD latices which contain
high levels of chlorine, so we recommend the antimony pentaoxide
be added to your formulation until the complete system passes
the required flame test.
|
| Formula
Example |
|
This simple FR application for the
finishing of nonwoven polyester fiber padding for automotive
interiors consists of a 'hard' PVC latex, Chemico A - 50,
water and some ammonia solution : To 10 parts Chemico A-50,
add 40 parts water with sufficient ammonia to bring the pH to 9,
mix the water and the A-50, add 50 parts PVC latex.
These ingredients are mixed, sprayed onto the nonwoven padding,
and heat cured.
|
| Benefits |
- Better penetration of the substrate.
- Less pigmenting or whitening effect for deep mass tone
colours.
- Easier handling and processing. Liquid dispersion will
not clog spray guns.
- Translucency for coatings, films and laminates.
- Easy compounding : no special dispersing equipment
required.
- High FR efficiency for minimal added weight or change in
hand.
|
|
CHEMICO is a trademark of
the CCPL The details contained in this documents are current as at
20.02.2003 and are for information purposes only. The statement are not
and should not be construed as a statement of fact, representation,
guarantee or warranty of any kind and do not constitute a specification.
Nothing contained herein is intended as a recommendation to use our
products so as to infringe any patents.
|